Daikin

Daikin 3 Ton G/E 90,000 BTU/Hr Packaged Rooftop Unit | 208-230/1

Discontinued Model
SKU #:DBG0361DH00001S-DAIMFG #:DBG0361DH00001S
DBG 3 to 5 Ton Commercial Gas Electric Rooftop
Daikin

Daikin 3 Ton G/E 90,000 BTU/Hr Packaged Rooftop Unit | 208-230/1

Discontinued Model
SKU #:DBG0361DH00001S-DAIMFG #:DBG0361DH00001S
$10,723.00 / EA

    Description

    The 3T DBG0361DH00001S Gas/Electric 90MBTU Packaged Rooftop with Standard Static Belt Drive is Built to Perform with Features that Help Provide Low Installation and Operation Costs, Superior Indoor Quality, Efficient Operation and Longevity

    Specifications

    • BrandDaikin
    • Compressor TypeScroll
    • Efficiency (AFUE)81%
    • Energy Efficiency Rating (EER)11-1/2
    • Filter Size (In.)(2) 20 X 25 X 2
    • Height (In.)39-7/8
    • Length (In.)74
    • RefrigerantR410A
    • Weight (lbs)573, 615
    • Width (In.)48-5/16
    • ManufacturerDaikin
    • Nominal Cooling Capacity (Tons)3
    • Nominal Cooling Capacity (Btu/Hr)36,000
    • Nominal Heating Capacity (Btu/Hr)90,000
    • Blower Motor DesignStandard Static Direct Drive
    • Stages of Cooling1 Stage
    • Factory Installed EconomizerNot Included
    • DisclaimerFor professional use only. Refer to all information, warnings and instructions on product and package labeling and accompanying documentation provided by the product manufacturer. Product must be used in accordance with such labeling and documentation.
    • Blower Motor Full Load Amps5.70A
    • Cabinet MaterialGalvanized Steel
    • Compressor Locked Rotor Amps79.00A
    • Compressor Rated Load Amps16.70A
    • Drain Connection (In.)3/4 NPT
    • Energy Efficiency Rating (SEER)14
    • Entering Air Temperature (EAT) Dry Bulb80 F
    • Entering Air Temperature (EAT) Wet Bulb67 F
    • External Static Pressure (In. WC)1/2
    • Fan Motor Full Load Amps0.95A
    • Fan Motor Horsepower Rating0.17
    • Fan Motor Quantity1
    • Fan Motor RPM810
    • Flow ConfigurationDownflow
    • Gas Heating TypeHigh Heating Range
    • Gas Valve Type2 Stage
    • Hertz60 Hz
    • Leaving Air Temperature (LAT) Dry Bulb62.1 F
    • Leaving Air Temperature (LAT) Wet Bulb59.1 F
    • Maximum Fuse Amps40.00/40.00A
    • Minimum Circuit Ampacity27.50/27.50A
    • Motor Horsepower3/4
    • Net Cooling Capacity (BTU/Hr)35300
    • Options IncludedFilter Drier, High Pressure Switch, Low Pressure Switch
    • Outdoor Design Temperature95 F
    • Sensible Cooling Capacity (BTU/Hr)27534
    • Total External Static Pressure (In. WC)0.55
    • Voltage (V)208-230/1