A |
Back to Top |
AC |
Air Conditioning |
|
AC |
Alternating Current |
|
ACH |
Air Changes per Hour |
|
ACM |
Asbestos Containing Material |
|
AEE |
Association of Energy Engineers |
|
AFD |
Adjustable Frequency Drive |
|
AFUE |
Annual Fuel Efficiency Ratio |
|
AHU |
Air Handling Unit |
|
AI |
Analog Input |
|
Anti-Ice Control |
same as a freeze stat or encapsulated pressure control |
|
AO |
Analog Output |
|
Aquastat |
controls the use of a water system. We sell the Honeywell aquastats. You can also use the Ranco ETC series of temp controls. |
|
ASHRAE |
American Society of Heating Refrigeration and Air Conditioning Engineers |
|
B |
|
Back to Top |
B |
Boiler |
|
BACnet |
A Data Communication Protocol for Building Automation and Control Networks |
|
BAS |
Building Automation System |
|
Bazooka |
636 concentric vent kit |
|
BCA |
Building Commissioning Association |
|
Bearshit |
cork tape |
|
BI |
Backward Incline |
|
BI |
Binary Input |
|
BO |
Binary Output |
|
BSLN |
Baseline |
|
BTU |
British Thermal Unit |
|
BTUH |
Brtish Thermal Units / Hour |
|
BY |
Base Year |
|
C |
|
Back to Top |
Can |
a small hermetic compressor |
|
CAV |
Constant Air Volume |
|
CD |
Cold Deck |
|
CDD |
Cooling Degree Days |
|
CEM |
Certified Energy Manager |
|
CFC |
ChloroFluoroCarbon |
|
CFM |
Cubic Feet per Minute |
|
CH |
Chiller |
|
CHW |
Chilled Water |
|
CHWP |
Chilled Water Pump |
|
CHWR |
Chilled Water Return |
|
CHWRT |
Chilled Water Return Temperature |
|
CHWS |
Chilled Water Supply |
|
CHWST |
Chilled Water Supply Temperature |
|
CLF |
Cooling Load Factor |
|
CLTD |
Cooling Load Temperature Difference |
|
COP |
Coefficient Of Performance |
|
CRAC |
Computer Room Air Conditioner |
|
CT |
Cooling Tower |
|
CV |
Constant Volume |
|
CVRMSE |
Coefficient of Variation of the Root Mean Square of the Error |
|
CWP |
Condenser Water Pump |
|
CWR |
Condenser Water Return |
|
CWRT |
Condenser Water Return Temperature |
|
CWS |
Condenser Water Supply |
|
CWST |
Condenser Water Supply Temperature |
|
CY |
Current Year |
|
D |
|
Back to Top |
DA |
Discharge Air |
|
DB |
Data Base |
|
DB |
Dry Bulb |
|
DC |
Direct Current |
|
DCV |
Demand Controlled Ventilation |
|
DD |
Degree Day |
|
DDC |
Direct Digital Control |
|
DH |
Duct Heater |
|
DI |
Digital Input |
|
DO |
Digital Output |
|
DP |
Dew Point |
|
DP |
Differential Pressure |
|
DX |
Direct Expansion |
|
E |
|
Back to Top |
EAT |
Entering Air Temperature |
|
ECM |
Electronically Commutated Motor |
|
ECM |
Energy Conservation Measure |
|
ECO |
Energy Conservation Opportunity |
|
EDH |
Electric Duct Heater |
|
EEM |
Energy Efficiency Measure |
|
EER |
Energy Efficiency Ratio |
|
EF |
Exhaust Fan |
|
Eggcrate |
this is a plastic grill material that can replace ceiling tiles. Part Number: 2-4-1/2-ALL |
|
EH |
Electric Heater |
|
EMS |
Energy Management System |
|
ESCO |
Energy Service Company |
|
EUH |
Electric Unit Heater |
|
EWT |
Entering Water Temperature |
|
F |
|
Back to Top |
FC |
Forward Curve |
|
FCU |
Fan Coil Unit |
|
FIM |
Facility Improvement Measure |
|
Firecracker |
Fan cycling control |
|
FLA |
Full Load Amps |
|
Flux |
Used to etch metal for filler (solder) to bold |
|
FMS |
Facility Management System |
|
FPM |
Feet Per Minute |
|
Freeze-Stat |
a switch to stop evaporators from icing up. (eg. AE1C-1-ECO or HH) |
|
FW |
Feed Water |
|
G |
|
Back to Top |
GPM |
Gallons Per Minute |
|
GUI |
Graphical User Interface |
|
H |
|
Back to Top |
HCFC |
Hydrochlorocfuorocarbon |
|
HD |
Hot Deck |
|
HDD |
Heating Degree Days |
|
HEPA |
High Efficiency Particulate Arresting |
|
HFC |
HydroFluoroCarbon |
|
HHV |
Higher Heating Value |
|
HHWP |
Heating Hot Water Pump |
|
HHWR |
Heating Hot Water Return |
|
HHWS |
Heating Hot Water Supply |
|
HL |
High Limit |
|
HPS |
High Pressure Steam |
|
HR |
Heat Recovery |
|
HRU |
Heat Recovery Unit |
|
HRV |
Heat Recovery Ventilator |
|
HSPF |
Heating Seasonal Performance Factor |
|
HVAC |
Heating Ventilation and Air Conditioning |
|
HWP |
Hot Water Pump |
|
HWR |
Hot Water Return |
|
HWS |
Hot Water Supply |
|
HWRT |
Hot Water Return Temperature |
|
HWST |
Hot Water Supply Temperature |
|
HX |
Heat Exchanger |
|
I |
|
Back to Top |
I/O |
Input Output |
|
Inducer Motor |
also known as a venter motor. It vents harmful gas out of the furnace through 636 pipe to the outside of the house or building |
|
IAQ |
Indoor Air Quality |
|
IPMVP |
International Performance Measurement and Verification Protocol |
|
IR |
Infra-Red |
|
J |
|
Back to Top |
Jellybean |
specific style of crimp connector |
|
K |
|
Back to Top |
King Valve |
The shut off valve on a condensing unit. This where refrigerant is charged and where the line set piping connects to |
|
L |
|
Back to Top |
LAT |
Leaving Air Temperature |
|
LHV |
Lower Heating Value |
|
Line Voltage Thermostat |
Used for electrical baseboards or anything using 120/208v to match amperage. Look for these Honeywell items |
|
LL |
Low Limit |
|
LON |
Local Operating Network |
|
LP |
Low Pressure |
|
LPS |
Low Pressure Steam |
|
LRA |
Locked Rotor Amps |
|
LWBT |
Leaving Wet Bulb Temperature |
|
LWT |
Leaving Water Temperature |
|
M |
|
Back to Top |
M&V |
Measurement and Verification |
|
MA |
Mixed Air |
|
MAT |
Mixed Air Temperature |
|
MCC |
Motor Control Center |
|
MUA |
Make-up Air Unit |
|
Muffin Motor |
3.3" unit bearing motor eg. R-5411 |
|
MX |
Metrix Utility Accounting System |
|
MZ |
Multi-Zone |
|
N |
|
Back to Top |
NC |
Normally Closed |
|
NEMA |
National Electrical Manufacturers Association |
|
NO |
Normally Open |
|
NPSH |
Net Positive Suction Head |
|
O |
|
Back to Top |
OA |
Outside Air |
|
OAP |
Outside Air Percentage |
|
OAT |
Outside Air Temperature |
|
OCS |
this stands for “Our Compressor Shop”. It is referring to internal purchases used for the business. It was called this when RSL operated their own compressor rebuild shop decades ago |
|
ODP |
Open Drip Proof |
|
OWS |
Operator Work Station |
|
P |
|
Back to Top |
Pancake |
636 low profile vent termination kit (1HT |
|
Pancake Drier |
stout suction line filter driers. ie C-145-S-TT-HH |
|
PC |
Performance Contracting |
|
PE |
Professional Engineer |
|
Penthouse Unit |
they are likely referring to a self-contained refrigeration system that is mounted on the top of a walk-in box. We stock the Bohn Pro3 |
|
PH |
Pre-Heat |
|
PID |
Proportional Integral Derivative |
|
PRV |
Pressure Relief Valve |
|
PRV |
Pressure Reducing Valve |
|
PTAC |
Packaged Terminal Air Conditioner |
|
Q |
|
Back to Top |
R |
|
Back to Top |
RA |
Return Air |
|
Rezpack/Respack |
this is short for “Residential Packaged Unit”. They are a rooftop square in shape that are typically 2-5 tons. In some parts of North America they are used in residential applications. |
|
RF |
Return Fan |
|
RH |
Reheat |
|
RH |
Relative Humidity |
|
RPM |
Revolutions Per Minute |
|
RTD |
Resistance Temperature Detector |
|
RTU |
Roof Top Unit |
|
S |
|
Back to Top |
SA |
Supply Air |
|
SAT |
Supply Air Temperature |
|
SC |
Shading Coefficient |
|
SEER |
Seasonal Energy Efficiency Ratio |
|
SF |
Supply Fan |
|
SHFG |
Solar Heat Gain Factor |
|
SHR |
Sensible Heat Ratio |
|
Silfos |
comes in 5 and 15% silver and is used to bond copper to copper. No flux required |
|
Silver Solder |
Silver solder required flux or comes pre fluxed and is used for bonding dissimilar metals |
|
Skeleton Motor |
specific style of motor used in small refrigeration applications. |
|
SP |
Set Point |
|
SP |
Static Pressure |
|
Super Hose |
Also known as High Pressure Control Hose. We stock the Ritchie yellow jacket product. Part #: 78712, 78718, 78724, 78730, 78736, 78748, 78760, 78772 |
|
SWP |
Steam Working Pressure |
|
T |
|
Back to Top |
T |
Temperature |
|
T |
Thermostat |
|
TEV |
Thermostatic Expansion Valve |
|
TOD |
Time Of Day |
|
TORR |
Millimeter of Mercury (mmHg) |
|
Trax/Traxx Oil/Traxx Oil Control |
Trax is an old brand name. The customer is likely looking for a Copeland oil level control – Part #: OMB-JB1 |
|
TXV |
Thermostatic Expansion Valve |
|
U |
|
Back to Top |
UH |
Unit Heater |
|
UV |
UltraViolet |
|
UV |
Unit Ventilator |
|
V |
|
Back to Top |
VAV |
Variable Air Volume |
|
VD |
Volume Damper |
|
Venter Motor |
also known as an inducer motor. It vents harmful gas out of the furnace through pipes to the outside of the house or building |
|
VFD |
Variable Frequency Drive |
|
VSD |
Variable Speed Drive |
|
VSP |
Variable Speed Pump(ing) |
|
W |
|
Back to Top |
WB |
Wet Bulb |
|
WC |
Water Column |
|
Window Shaker |
refers to the window mounted air conditioners. We stock Friedrich, and have access to Comfort-aire and Amana |
|
X |
|
Back to Top |
Y |
|
Back to Top |
YTD |
Year To Date |
|
Z |
|
Back to Top |